Worcester Bosch Boiler Error Codes: Full UK Guide (2025)

All Worcester Bosch boiler fault codes explained — causes, fixes, UK repair costs, and when to call a Gas Safe engineer.

Worcester Bosch Boiler Error Codes — illustrative photo for UK home emergency and boiler cover guide

Worcester Bosch Boiler Error Codes: Full UK Guide (2025)

Worcester Bosch boilers are some of the most reliable in the UK — but like any heating system, they can display error codes when something isn't working correctly. This guide explains every major Worcester Bosch error code, what it means, how to fix it, and typical repair costs across the UK.

This guide is written for homeowners in London, Manchester, Birmingham, Leeds, Glasgow, Liverpool, Bristol and everywhere else in the UK.

Need emergency help? Visit our Boiler Cover or book a Boiler Service.

EA Error Codes (Ignition / Flame Problems)

EA 227 — Ignition Failure

Meaning: The boiler cannot ignite.

Causes:

Fix:

Typical Repair Cost (UK): Ā£90–£250


EA 229 — Flame Not Detected

Meaning: Boiler ignites but cannot detect flame.

Common in: Older Worcester 24CDi, 28CDi, Greenstar i.

Fix: Engineer must check: flame sensor, PCB, gas valve.

Cost: Ā£120–£350

A Series Errors (Temperature & Sensor Faults)

A21 — Flow Temperature Sensor Fault

Meaning: The flow temperature is reading too high or too low.

Fix: Sensor needs recalibration or replacement.

Cost: Ā£80–£180


A28 — Return Temperature Sensor Fault

Meaning: Temperature difference too high.

Fix: Bleed radiators, check pump.

Cost: Ā£90–£160

E Series Errors (Overheating & Serious Faults)

E9 — Overheat or Heat Exchanger Blockage

Risk level: High

Causes:

Fix: Must be checked by a Gas Safe engineer.

Cost: Ā£150–£450

H Series Errors

H07 — Low System Pressure

Meaning: Water pressure below 1.0 bar.

Fix: Top up using filling loop.

If pressure drops again → leak likely.

Cost: £0 (self fix) to £180 for leak tracing.

CE / C Errors (Communication & Control Faults)

CE 207 — Communication Error

Meaning: PCB cannot communicate with control unit.

Fix: Engineer repair — likely PCB.

Cost: Ā£200–£450


C6 — Fan Speed Fault

Meaning: Fan cannot reach correct speed.

Fix: Fan replacement.

Cost: Ā£180–£350

Lockout Codes

L2 — Flame Loss / Lockout

Meaning: Boiler tried to fire but failed.

Fix: Reset boiler → If recurring, engineer needed.

Cost: Ā£120–£250

When to Call a Gas Safe Engineer

You must NOT attempt repairs if the issue involves:

If unsure, book a professional:

Typical Worcester Bosch Repair Costs (UK 2025)

Fault Type Typical Cost
Ignition faults Ā£120–£250
Pressure faults Ā£80–£150
PCB replacement Ā£250–£450
Fan replacement Ā£200–£350
Heat exchanger Ā£400–£700
Annual boiler service Ā£70–£90

These are average UK prices — London tends to be 10–15% higher, while the North West and Midlands are typically cheaper.

Final Advice

Worcester Bosch error codes are often straightforward — but repeated faults signal a deeper problem. If your boiler is older than 10–12 years, breakdowns become more common.

Stay protected with: